Fire & Safety System

Fire Detection & Safety Systems

Fire safety is a non-negotiable requirement for any commercial, industrial, or residential building. Sreewari Engineers provides complete fire detection, alarm, suppression, and evacuation system solutions in compliance with NBC (National Building Code), TAC, and local authority requirements.

Our certified fire safety engineers design systems that provide early warning, rapid suppression, and safe evacuation pathways — protecting both lives and assets.

All our fire safety installations comply with NBC 2016, TAC regulations, and NFPA standards with proper certification on completion.

Fire safety system installation

Fire Safety Services

  • Addressable and conventional fire alarm systems
  • Automatic sprinkler system installation
  • FM-200 and CO₂ suppression systems
  • Smoke detection system design and installation
  • Emergency lighting and exit signage
  • Fire hydrant and hose reel systems
  • Annual fire safety inspection and AMC

Advanced Fire Protection & Public Health Engineering

Complete fire suppression, smoke management, and fire hydrant infrastructure built to strict NBC 2016 and NFPA standards — zero regulatory exposure for our clients.

Smoke Spill & Mechanical Pressurisation

Engineered smoke extraction systems for basements, atriums, and covered car parks. Staircase pressurisation and corridor smoke spill integrated with fire alarm control panels for code-compliant life-safety performance.

  • NFPA 92 & NBC 2016 compliance
  • CFD smoke modelling for complex spaces
  • Fire damper & MCC integration
Internal Fire Hydrant Networks

Fire pump rooms, wet risers, landing valves, hose reels, and jockey pump systems — designed and installed per NBC 2016 and NFPA 14 for comprehensive building-level fire fighting capability.

  • Electric & diesel pump sets
  • Terrace-level overhead tank sizing
  • Hydraulic calculation & pressure testing
Automatic Sprinkler Systems

Wet pipe, dry pipe, and pre-action sprinkler networks engineered for light, ordinary, and extra-hazard occupancies. All designs conform to NFPA 13 with hydraulically calculated pipe sizing.

  • Density/area method hydraulic design
  • Concealed, pendent & sidewall heads
  • Deluge systems for high-hazard areas
External Hydrant & PHE Systems

Yard hydrant networks, monitor nozzles, and fire-fighting water supply infrastructure. Hydro-pneumatic plumbing systems with VFD-driven pumps for constant-pressure water distribution across multi-level buildings.

  • NFPA 24 underground mains design
  • VFD pumping for constant-pressure supply
  • STP & ETP integration capability

Ensure Fire Safety Compliance Today

Contact our fire safety specialists for a comprehensive fire risk assessment.

Chat with us!